[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Discharge rate error on HP nx6125
When my nx6125 is running from batteries, the discharge rate is reported
as about 30,000mA - this is about an order of magnitude high. The
capacity warning levels (~5% and 1%) also appear unrealistically low.
turion% acpiconf -i 0
Design capacity: 4725 mAh
Last full capacity: 4725 mAh
Technology: secondary (rechargeable)
Design voltage: 11100 mV
Capacity (warn): 237 mAh
Capacity (low): 48 mAh
Low/warn granularity: 100 mAh
Warn/full granularity: 100 mAh
Model number: Primary
Serial number: 14370 2005/09/22
Type: LIon
OEM info: Hewlett-Packard
State: discharging
Remaining capacity: 98%
Remaining time: 1:43
Present rate: 29870 mA
Voltage: 12090 mV
--
Peter Jeremy